Relevant Standard Testing Requirements
Safety Test for Single Batteries: The Heating Test shall be carried out in accordance with the following steps:
1.1 Charge the single battery according to the method specified in 6.1.3.
1.2 Place the single battery in a temperature chamber. For lithium-ion batteries, the temperature of the temperature chamber shall be increased from room temperature to 130°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 30 minutes before stopping the heating. For nickel-metal cyanide batteries, the temperature of the temperature chamber shall be increased from room temperature to 85°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 2 hours before stopping the heating. Observe for 1 hour.
Safety Test for Battery Modules: The Heating Test shall be carried out in accordance with the following steps:
1.1.1 Charge the batteries in the battery module according to the method specified in 6.1.4.
1.1.2 For lithium-ion batteries, the temperature of the temperature chamber shall be increased from room temperature to 130°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 30 minutes before stopping the heating. For nickel-metal cyanide batteries, the temperature of the temperature chamber shall be increased from room temperature to 85°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 2 hours before stopping the heating. Observe for 1 hour.
Name of the equipment | Seawater immersion test device |
Model | MBS-JP09 |
The size inside the pool | 3000W*2000D*1500H mm |
External size | 4000W*3000D*4500H mm |
The size of the hanging basket | 2500W*1500D*1000H mm |
Maximum test space | 2500W*1500D* 1000H mm |
Maximum load | 1000kg |
Equipment weight | Weigh 3 tons |
Equipment power supply | AC380V 5.5kW |
Other functions | Automatic inlet, drain and circulation functions. PLC touch screen control + remote computer control. Automatic lifting of hanging basket. |