Step into the realm of advanced testing solutions with our High Performance Temperature Humidity Chamber, a pinnacle of engineering crafted for meticulous high and low-temperature assays on an extensive range of electrical products, components, and materials. This versatile marvel from MENTEK not only performs constant gradient and sudden mutation testing but also excels in wet heat trials. Proudly adhering to Chinese national standards/T10586-2006 and T10592-2008, it guarantees impeccable precision and steadfast reliability.
Model |
MBS-IS200 |
Rated load |
10 Kilogram(Including fixtures and test products) |
Table size |
Length 200×Width 200 |
Impact waveform |
Semi-sine wave |
Peak acceleration (semi-sine wave) |
150~ 15,000 m/s² |
Pulse duration (semi-sine wave) |
0.6-20ms |
External size |
W1000×L500×H2700mm |
Equipment weight |
1500 Kilogram |
Impact form |
Free fall |
Maximum drop height |
1500mm |
Power supply |
3-phase 380V, 50/60Hz |
Hydraulic source |
Random configuration |
Ambient temperature |
0~40ºC |
Environmental humidity |
Less than 85% |
Reliability |
The average fault-free cumulative working time is ≥1000h |
Measurement and control system |
ShockDAQ.Impact and collision measurement and control system |
Applicable standards |
GJB.150,GJB.360,GJB.548,China National Standard/T2423,GJB.1217 |
Identification criteria |
Acceleration amplitude, pulse width, uniformity and lateral motion ratio satisfyJJG.541-88 |
Note: Customize the dimensions to perfectly suit your detailed specifications.
Relevant standard test requirements
Exceeds standards: IEC62133-2012, UL1642, UN38.3, and 31241-2014, ensuring top-tier quality.
Refer to section 4.5 for the sample guidelines. Conduct the acceleration impact test post full charge, executing it sequentially in three orthogonal directions. For intricate details, please refer to test method 7.4.
Subsequent to the experiment, proceed with one discharge and charging cycle following the method outlined in 4.5. The sample must remain safe-no ignition, explosion, or leakage.
Our cutting-edge equipment adheres to the most stringent testing standards:
National Standard/T2423.1-2008 Test A: Low Temperature National Standard/T4243.2-2008 Test B: High Temperature (Partial) National Standard/T2433.3-2006 Test Cab: Constant Humidity and Heat Chinese National Standard/T2423.4-2008 Test. Decibel: Change, Damp Heat China National Standard/T2423.34-2012 Test Z/AnnoDominique: A blend of temperature and humidity, or other specific tests within the equipment's performance capabilities.
Structure of the Testing Chamber
The testing chamber's exterior is meticulously constructed from galvanized color steel plates, promising robustness and long-lasting service.
Inside, the chamber is crafted with SUS304 stainless steel, featuring adjustable side-mounted hanging strips and a versatile test track frame. Insulated by a minimum of 10 cm thick rigid polyurethane foam and glass wool, it ensures superior thermal retention. The door's inner and outer frames are engineered with premium electric wood chicken glass fiber board, while the double-channel series silicone foam sealing strip guarantees unmatched resistance across a broad temperature spectrum.
Advanced Experimental Space Air Circulation:
Our sophisticated air supply system, powered by multi-blade aluminum wind turbines, expertly handles extreme temperatures. Driven by motors, these turbines ensure efficient air delivery to upper louvers, with bottom return flow, achieving exceptional uniformity of less than 2 º C throughout an expansive range of -70~100 º C-a precision benchmark acknowledged globally.
Controller Operating System
Equipped with a state-of-the-art low-power (8W) temperature and humidity control device, we offer temperature control precision of ± 3 º C, guaranteeing steadfast and consistent performance.
1. High Resolution Screen:
Enjoy impeccable clarity on a 7-inch TET true color LCD resistive touch screen, with an outstanding resolution of 800 * 480 pixels.
2. High Program Capacity:
With an expansive memory accommodating 1000 programs/1000 segments, 999 total loops, and 999 partial loops, our system features 10 program linking options, along with real-time temperature curve displays for immediate access.
3. High Data Storage Capacity:
Effortlessly transfer 300 days' worth of historical data using storage operation mode, directly uploadable to a hard disk or network cable, or seamlessly integrate into the controller for streamlined data management.
4. Easy Connection:
Our state-of-the-art controller is equipped with LAN standard Ethernet communication capabilities, enabling seamless connectivity for up to 16 devices through a single software interface. Effortlessly integrate into your network with the machine's outflow interface, empowering you with remote program control, real-time monitoring, and historical curve playback for comprehensive management.
Heating and Humidification System
Crafted with precision, our system utilizes high-grade bare wire nickel chromium alloy electric heating tubes. This ensures minimal thermal inertia and heating overshoot, delivering precision fluctuations and high efficiency, making it the epitome of perfection in heating solutions.
1. Humidifier:
Discover unrivaled uniformity with our innovative humidification system. Utilizing a humidification cylinder via the boiler method ensures consistent, quality results. The surface humidification (water plate method) offers swift operation with enhanced control precision, effectively removing impurities such as scale. Its dyeing capability and exceptional low humidity performance make maintenance a breeze, keeping your system pristine. The humidification tube is encased in a seamless stainless steel shell with insulation resistance over 50M Ω, and features an advanced anti-dry burning controller to ensure safety.
2. Optimizing Water Usage and Energy Efficiency:
Our innovative front-mounted, 25L high-capacity water tank incorporates a quick connection design, simplifying the water and electricity setup for hassle-free disassembly and cleaning. Achieve precise dehumidification across three distinct humidity zones, significantly reducing water usage while maintaining compliance with national standards at high temperatures and humidity levels, such as 85 ºC and 85% RH. The closed design, with point cooling and dehumidification systems deactivated, greatly minimizes water consumption.
Invest in cutting-edge equipment, meticulously engineered to thrive even under the most demanding testing conditions.
1. Choose the Ideal Circulating Air Mode: Courtyard Air Supply or Variable Speed Motor
When your product specifications necessitate precise wind speed requirements, our tailored solution is the ultimate choice for optimized performance.
2. Select the Right Water Supply System: RO Reverse Osmosis
For all your humidification needs, our equipment is designed with a reliance on pure water. The automatic water production system continuously provides pure water, saving time and enhancing convenience.
3. Advanced Polymer Film/Rotor Dehumidification System
For operations necessitating sustained low-temperature and low humidity testing, our cutting-edge cellular chemical dehumidification system is indispensable, achieving a remarkable humidity range of up to 10 ºC/10% RH or even lower.
4. LN.Two/ .LCO.2
Explore our meticulously curated range of professional products, imported from Europe and the United States, available in comprehensive specifications to suit your every need. LN.Two/ .LCO.2
Our sophisticated solenoid valves, paired with integrated control systems, are designed to meet your swift testing requirements, enabling rapid acceleration and efficient temperature reduction.
5. State-of-the-Art Ultrasonic Cooling and Humidification System
For dynamic high heat load testing in extreme temperature and humidity conditions, our ultrasonic cooling and humidification system is expertly engineered to fulfill these stringent demands, serving as a crucial auxiliary system.
6. Enhance Functionality with a Glass Inner Door and Manual Operation Features
To support frequent test subject movements and operations, our glass inner door (∧ 125Mm * Ea.) with manual operation capabilities effectively mitigates environmental impacts when the chamber door is opened.
7. Real-Time Data Acquisition Recorder
For the simultaneous recording of multiple temperature readings from both the testing environment and the test object, our recorders are built to comply with industry standards. A tape recorder is your exclusive solution for achieving these specific requirements with precision.
8. Advanced Computer Connection Operation Recording Software
d5995836
Company Profile
Certifications
Ship to Client's Factory
Our Partners
Packaging & Shipping