Technical parameters of 6-ton vibration table body | |||
Sinusoidal thrust | 6400kgf | N*M Allowable partial load moment | >1100 |
Random thrust | 6400kgf | Equivalent mass of moving parts | 64kg |
(6ms) Impact thrust | 12800kgf | Load connection point | 17 |
Frequency Range | DC-2.700Hz | Countertop screw size (standard) | M12 |
Continuous displacement | 51mm | Tablet screw layout (diameter, circumference) | 8*200mm; 8*400mm |
Impact displacement | 63.5mm | Axial vibration isolation frequency | <3Hz |
Maximum speed | 2m/s | Maximum load | 800kg |
Maximum acceleration | 981m/s | Magnetic flux leakage | ≤1mT |
Moving circle diameter | 480mm | (L*W*H) Size (no packaging) | 1605*1130*1375mm |
First order resonant frequency | 2250Hz | Shaking table weight (no package) | 4500kg |
Technical parameters of power amplifier | Technical parameters of fan | ||
Maximum output power | 60KVA | Fan power | 30kW |
Signal to noise ratio | >65dB | Air volume | 1.42m/s |
Rated output voltage | 120Vrms | Wind pressure | 0.094kgf/cm |
Amplifier efficiency | >92% | Duct diameter | 200mm |
System protection | Featuring multiple performance protections | (L*W*H) Size (no packaging) | 990*1455*2468mm |
(L*W*H) Size (no packaging) | 550*800*2070mm | Weight (no packaging) | 510kg |
Amplifier weight (without packaging) | 780kg |
System working environment requirements | Purchase configuration | ||
temperature | 0-40ºC | sliding table | Vertical expansion of the table |
humidity | 0-90% | Mobile device | Insulation board |
Power requirements | 3AC, 380V±10%, 50Hz,115KVA | Power amplifier remote control | Fixture |