Precision Battery Pack Horizontal Extrusion Needle Testing Machine for Quality Assurance
Product Description
Relevant standard test requirements
1.1 The test object is the battery pack or system
1.2 Pressurization according to the following conditions
1.2.1 Extruded plate form: plate garden cylinder with a radius of 75mm, the long line of semi-cylindrical body is larger than the test. The height of the object, but not more than 1mm.
1.2.2 Squeezing direction: X and Y direction (the driving direction of the car is the X axis, and the other horizontal direction perpendicular to the driving direction is the Y axis).
1.2.3 Squeezing degree: Stop squeezing when the squeezing force reaches 200KN or the extrusion deformation reaches 30% of the overall size of the squeezing direction.
1.2.4 Maintain for 10min and observe for 1h
1.3 Requirements: The battery pack or system does not catch fire or explode and so on.
Name of the equipment |
Squeezing needle and piercing all-in-one machine |
Model |
MBS-JZ500 |
Pressure |
50 T |
Squeezing method |
Crosswise |
Box structure |
Horizontal box structure |
Test space (W*H*D) mm |
2500*2000*2000 |
Power supply voltage |
Ac380V 50Hz |
Squeezing speed |
1-10mm/s (Adjustable) |
Needle puncture speed |
1-100mm/Small size (Adjustable) |
Test conditions |
Force, displacement (deformation) , voltage, one of the three or a combination of three |
Driving mode |
Oil-pressure servo drive |
Squeezing accuracy |
≤±1% (FSR.) |
Acupuncture accuracy |
≤±1% (FSR.) |
The amount of extrusion deformation |
0~ 100% multi-gear work cloth setting, can be realized continuously multi-layer extrusion deformation loading |
Squeezing fixture |
Shaped squeezing head (400*150mm) flat squeeze plate, arc squeeze plate (radius75mm). It can be according to different standard optional different fixtures |
Data acquisition module |
Multiple data acquisition module, temperature, voltage and current are collected. The road adopts N×4 mode. It is convenient to expand when necessary in the future, make sure that the data is correct |
Safety alarm |
Leakage, overheating, overvoltage, overload, overcurrent protection, abnormality sound and light alarm, smoke alarm, etc. |
Control method |
Device host and remote PC control, device body and console. Separate, can be controlled remotely, and the operator should stay away from the test area. The longest long-distance distance can reach 50 meters, and the standard line length is 10m. It can effectively protect the safety of testers. |