Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester

Product Details
Customization: Available
After-sales Service: Support Operation Guidance
Power Supply: 220/380V
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (29)
  • Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
  • Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
  • Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Certifications
  • Ship to Client′s Factory
  • Our Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
MBS-QY
Certification
CE
Warranty
1 Year
City
Dongguan, Guangdong
Uses
Battery Low Pressure Testing
Purpose
Battery Low Pressure Tester
Customize
Acceptable
Transport Package
Wooden Box
Specification
50*50*50cm
Trademark
MENTEK
Origin
China
HS Code
9030339000
Production Capacity
1000PCS/1year

Product Description

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Product Description

Relevant Standard Testing Requirements
Meet the standards: IEC62133-2012, UL1642, UN38.3 and 31241-2014 standards

Low Air Pressure: After fully charging the battery according to the test method specified in 4.5.1, place the battery in a vacuum chamber at a temperature of 20°C ± 5°C. Evacuate the chamber to reduce the internal pressure to 11.6 kPa (simulating an altitude of 15,240 m) and maintain this state for 6 hours. The battery should not catch fire, explode, or leak liquid.

Main Features
Adopt a high-quality 5mm SUS304 stainless steel inner pressure-bearing box body. The overall pressure-bearing strength design capacity is greater than 10t per square meter, and it is resistant to high and low temperatures and not prone to oxidation.

Reinforce the inner wall of the outer box to enhance the force support of the outer box.

The thermal insulation filling material is a special vacuum composite pressure-bearing thermal insulation material, which has strong pressure-bearing capacity and will not break under high-pressure conditions.

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric TesterMain Parameters

Model MBS-QY125 MBS-QY216 MBS-QY512 MBS-QY1000
Temperature range Normal temperature
Display mode PLC Touch screen display (7-inch touch screen)
Unit Kpa
Inner box size W*H*D mm 500*500*500 600*600*600 800*800*800 1000*1000*1000
Outer box size W*H*D mm 850*1680*1300 950*1680*1400 1150*1780*1600 1350*1780*1800
Inner wall materials Stainless steel plate SUS304
Outer box material Double-sided galvanized steel plate, surface spraying treatment
Pressure-bearing type Internal pressure
Time keeping time Four digits display 0~9999 (H hours, M minutes, scan be switched in seconds)
Observation window The door of the box is equipped with a window. The window glass is made of multi-layer vacuum glass, with automatic defrosting function, the glass surface film electronic heating can ensure that the glass surface is free of frost and condensation during any test.
Atmospheric pressure 5kPa-100kP(Adjustable)
Air pressure fluctuations ≤5%
Vacuum degree The standard requirement is 11.6kPa, vacuum representation value-89.7kPa.
Power supply AC220V 50Hz  380V 50Hz
USB interface Test data can be exported
Note: Tailor the dimensions of the chamber to perfectly align with your specific operational needs, delivering unparalleled flexibility and precision within your testing configurations.

 
Structural Process
1. Company's Hardware Equipment:
1 imported German laser machine; 1 Amada AIRS - 255NT punching machine from Japan; more than 10 German carbon dioxide welding machines and argon arc welding machines. We use Autodesk Inventor 3D drawing software for 3D sheet metal disassembly drawing and virtual assembly design.

2. The outer shell is made of high - quality galvanized steel plates and finished with electrostatic powder spraying and baking paint.

3. The inner chamber is made of imported SUS#304 stainless steel and adopts the argon arc full - penetration welding process to prevent the leakage and penetration of high - temperature and high - humidity air inside the chamber. The rounded - corner design of the inner chamber liner can better drain the condensate water on the side walls. 
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Refrigeration System Technology
1. 3D Refrigeration System Management Drawing.

2. Frequency Conversion Control Technology of the Refrigeration System: In the frequency conversion refrigeration system, even if the power supply frequency of 50Hz is fixed, the frequency can be changed through the frequency converter, thereby adjusting the rotational speed of the compressor, and making the cooling capacity change continuously. This ensures that the operating load of the compressor matches the actual load inside the test chamber (that is, when the temperature inside the test body rises, the frequency of the compressor increases to enhance the cooling capacity; conversely, when the temperature drops, the frequency of the compressor decreases to reduce the cooling capacity). This greatly saves unnecessary losses during operation and achieves the goal of energy conservation. At the beginning of the operation of the test chamber, the frequency of the compressor can also be increased to enhance the capacity of the refrigeration system and achieve the purpose of rapid cooling. The test chamber adopts a frequency conversion refrigeration system, which can accurately control the temperature inside the chamber, keep the temperature inside the chamber constant with small temperature fluctuations. At the same time, it can also ensure the stable suction and discharge pressures of the refrigeration system, making the operation of the compressor more stable and reliable. Electronic Expansion Flow Servo.
Refrigeration system technology and other energy-saving technologies
1. VRF technology based on the principle of PID + PWM (the electronic expansion valve controls the refrigerant flow according to the thermal energy working conditions) is adopted. The VRF technology based on the principle of PID + PWM (refrigerant flow control) enables energy-saving operation at low temperatures (the electronic expansion valve controls the refrigerant flow servo according to the thermal energy working conditions). In the low-temperature working state, the heater does not participate in the operation. By adjusting the refrigerant flow and direction through PID + PWM, and regulating the three-way flow of the refrigeration pipeline, the cold bypass pipeline, and the hot bypass pipeline, the temperature of the working chamber can be automatically kept constant. In this way, under low-temperature working conditions, the temperature of the working chamber can be automatically stabilized, and the energy consumption can be reduced by 30%. This technology is based on the ETS system electronic expansion valve of the Danish company Dan-foss and can be applied to adjust the refrigeration capacity according to different requirements for refrigeration capacity. That is, it can realize the adjustment of the refrigeration capacity of the compressor when different cooling rate requirements are met.

2. The technology of grouped design of two sets of compressors (large and small) can automatically start and stop according to the load working conditions (large series design). The refrigeration unit is configured with a binary cascade refrigeration system composed of a set of semi-hermetic compressors and a set of fully hermetic single-stage refrigeration systems. The purpose of the configuration is to intelligently start different compressor units according to the load working conditions inside the chamber and the requirements for the cooling rate, so as to achieve the best matching between the refrigeration capacity working conditions inside the chamber and the output power of the compressor. In this way, the compressor can operate in the best working condition range, which can extend the service life of the compressor. More importantly, compared with the traditional design of a single large set, the energy-saving effect is very obvious, and it can reach more than 30% (cooperating with the VRF technology during short-time constant temperature control).
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Refrigeration circuit technology

The electrical components shall be installed according to the power distribution assembly drawings issued by the Technology Department during the power distribution layout operation.

Internationally renowned brands shall be selected: Omron, Sch-neider, and German Phoenix terminal blocks.

The wire codes shall be clearly marked. A time-honored domestic brand (Pearl River Cable) shall be selected to ensure the quality of the wires. For the control circuit, the minimum size of the selected wire is 0.75 square millimeter RV soft copper wire. For all main loads such as the motor compressor, the wire diameter shall be selected in accordance with the safety current standard for wiring in the EC wire trough.
The cable openings of the compressor terminal box shall be treated with sealant to prevent the terminals in the terminal box from short-circuiting due to frosting.

All the fixing screws of the terminals shall be tightened with the standard fixing torque to ensure reliable fastening and prevent potential hazards such as loosening and arcing. 
Refrigeration series process
1. Standardization

1.1 Standardization of the piping process and welding of high-quality steel pipes; The piping layout shall be carried out in accordance with the standards to ensure the stable and reliable operation of the machine model system.

1.2 The steel pipes are bent in one piece by an imported Italian pipe bender, which greatly reduces the number of welding points and the internal pipe oxides generated during welding, and improves the reliability of the system!
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
2. Pipe Shock Absorption and Support

2.1 MENTEK has strict requirements for the shock absorption and support of the refrigeration copper pipes. Taking full account of the shock absorption situation of the pipes, circular arc bends are added to the refrigeration pipes, and special nylon fixing clamps are used for installation. This avoids the pipe deformation and leakage caused by circular vibration and temperature changes, and improves the reliability of the entire refrigeration system.

2.2 Oxidation-free Welding Process As is well known, the cleanliness inside the pipes of the refrigeration system is directly related to the efficiency and service life of the refrigeration system. MENTEK adopts standardized gas-filled welding operation to avoid a large amount of oxide contamination generated inside the pipes during welding.
 
Company Profile

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric TesterBattery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester

Certifications

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Ship to Client's Factory

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
 
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester
 
Our Partners

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester

Packaging & Shipping

Battery Pack Low Pressure Testing Chamber for Accurate Lithium Power Low-Atmospheric Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now