| Customization: | Available |
|---|---|
| After-sales Service: | Support Operation Guidance |
| Power Supply: | 380V |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Features
1. The two-chamber impact method is adopted, which can shorten the test temperature recovery time and enable more stringent test conditions to be carried out.
2. The three-chamber impact method is adopted, and normal temperature exposure can be added during high and low temperature impact conditions.
3. The large two-chamber impact chamber can be designed as a left-right translation type according to requirements.




Main Parameters
| Model | MTS-050 | MTS-100 | MTS-150 | MTS-200 | MTS-300 | |||
| Machine size W*H*D (cm) | 35*40*36 | 50*50*40 | 60*50*50 | 65*50*62 | 90*50*67 | |||
| Box size W*H*D (cm) | 135*175*137 | 140*180*137 | 150*185*150 | 155*185*165 | 180*185*170 | |||
| Pre-heating temperature range | +60ºC~+200ºC | |||||||
| Pre-cooling temperature range | -0ºC~-78ºC | |||||||
| Property | Test temperature range | -60ºC~+150ºC | ||||||
| -10ºC~40ºC; 10ºC~65ºC | ||||||||
| Temperature fluctuation | ±0.5ºC | |||||||
| Temperature conversion time | 5min | |||||||
| Preheating box heating time | ºC | 150 | 150 | 150 | 150 | 150 | ||
| min | 30 | 40 | 40 | 40 | 40 | |||
| Cooling time of pre cooling box | ºC | -40,-55,-65 | -40,-55,-65 | -40,-55,-65 | -40,-55,-65 | -40,-55,-65 | ||
| min | 70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | |||
| Material | Casing | High strength cold-rolled steel plate double-sided fine powder baking paint | ||||||
| Inner wall | SUS # 304 Stainless Steel 2B Panel | |||||||
| Thermal insulation material | Glass fiber+polyurethane foam | |||||||
| System | Fan | Centrifugal fans with different power and speed are used for high temperature box, low temperature box, and test box respectively | ||||||
| Heater | High quality nickel chromium alloy heater | |||||||
| Cooling system | Fully enclosed compressors imported from France or semi enclosed compressors imported from Germany. Binary cascade refrigeration+finned evaporator+pure aluminum accumulator | |||||||
| Controller | Original Japanese imported 7-inch TFT touch screen | |||||||
| Accessory | 2 compartments, 1 (optional lead hole), 1 recorder (optional) | |||||||
| Protector | No fuse switch, compressor overpressure, overheating, overcurrent protection, fuse, water flow protection. Phase sequence protection, oil pressure protection, and pressure relief protection. Low pressure protection, pneumatic cylinder protection, temperature limit protection | |||||||
| Electric power (kW) | AC3380V, 50Hz | |||||||
| 20,21,22 | 20,21,22 | 22,23,25 | 28,38,45 | 30,40,50 | ||||