Advanced Industrial Water Chiller Testing Machine Environmental Analysis Chamber
Product Description
Product Introduction
High and low temperature integrated temperature control equipment is applied to the high-temperature operation test, low-temperature operation test, high and low temperature alternating test, product heat dissipation test, internal channel flow resistance, pressure drop and sealing test of the products to be tested.
Heat-conducting Medium
Automotive antifreeze, ethylene glycol. When controlling the temperature, it is possible to choose to control the flow rate or pressure; it is equipped with a magnetic circulation pump to ensure the transportation of high and low temperature and high viscosity liquids; frequency conversion adjustment or proportional regulating valves are used to control the flow output, enabling adjustment within the total range of 5% to 100%. It is widely applicable to the extreme performance tests, rapid heating and cooling thermal shock tests, as well as comprehensive environmental adaptability evaluation tests of products such as new energy battery packs, batteries, modules, battery cells, motors and controllers, chargers, DC/DC converters, and electronic pumps.



Equipment Features
1. The temperature control range can be extended to - 40°C ~ 150°C.
2. The circulation pump is a high and low temperature resistant magnetic vortex pump. A flow sensor is installed at the equipment outlet. The frequency converter controls the rotational speed of the coolant pump according to the data of the flow sensor and the parameters set by the host computer, accurately adjusting the output flow of the coolant pump.
3. The temperature control system uses a PT100 armored temperature sensor to collect temperature data and a PLC controller as the temperature controller to automatically control the temperature of each node in the whole system.
4. The system (optional) adopts CAN/RS485/LAN communication to interact with the host computer, realizing functions such as remote setting of system temperature, standby/operation selection, and temperature query.
5. The equipment is equipped with various safety warning systems. There are warning prompts such as high and low temperature compressor overheat protection, high and low pressure protection, liquid tank level warning, high and low temperature warning, and comprehensive fault alarm.
Main Parameters
|
Model |
MLC-5 |
MLC-7.5 |
MLC-10 |
MLC-15 |
MLC-20 |
MLC-30 |
|
Flow range |
1-15L/min |
1-25L/min |
1-25L/min |
2-40L/min |
2-40L/min |
1-25L/min |
|
Temperature range |
-40°C~100°C |
|
Temperature control accuracy |
±0.5°c |
|
Temperature display |
0.1°c |
|
Cooling medium |
The freezing point is below - 45°C. It is ethylene glycol antifreeze. |
|
Flow control accuracy |
±0.2L/min |
|
Pressure control accuracy |
±2kPa |
|
Pressure display |
0-300kPa |
|
Heating power |
5kW |
6kW |
10.5kW |
10.5kW |
15kW |
15kW |
Refrigeration Capacity (no - load) |
25°c |
5kW |
7.5kW |
10kW |
15kW |
20kW |
30kW |
0°c |
5kW |
7.5kW |
10kW |
15kW |
20kW |
30kW |
-20°c |
2kW |
3kW |
4kW |
5kW |
7kW |
8kW |
-30°c |
1kW |
2kW |
3kW |
4kW |
5kW |
6kW |
-40°c |
/ |
1kW |
1kW |
1.5kW |
2kW |
3kW |
|
Average cooling rate |
4°c/min |
4°c/min |
4°c/min |
5°c/min |
5°c/min |
6°c/min |
|
Average heating rate |
4°c/min |
4°c/min |
5°c/min |
5°c/min |
6°c/min |
7°c/min |
|
Chilled water interface |
DN15 |
DN20 |
DN25 |
DN25 |
DN25 |
DN25 |
|
Cooling method |
air-cooled/water-cooled |
air-cooled/water-cooled |
air-cooled/water-cooled |
air-cooled/water-cooled |
water-cooled |
water-cooled |
|
Power supply requirements |
380V/50Hz |
|
Curve display |
Supply and return liquid pressure
Supply and return liquid temperature
Supply liquid flow rate |
|
Programming operation |
It can program 30 sets of programs. Each program can have 40 segments of steps. |
|
Data saving |
30 days of operation data |
|
Data export |
It supports export via USB2.0/3.0. |
|
Communication |
CAN /RS485/ LAN |
|
Optional configuration |
Automatic liquid filling
Automatic purging / Manual purging
Maintain pressure |
Note: Customization can be made according to the actual size requirements of the user.
Structural technology
Structural Process
1. Company's Hardware Equipment:
1 imported German laser machine; 1 Amada AIRS - 255NT punching machine from Japan; more than 10 German carbon dioxide welding machines and argon arc welding machines. We use Autodesk Inventor 3D drawing software for 3D sheet metal disassembly drawing and virtual assembly design.
2. The outer shell is made of high - quality galvanized steel plates and finished with electrostatic powder spraying and baking paint.
3. The inner chamber is made of imported SUS#304 stainless steel and adopts the argon arc full - penetration welding process to prevent the leakage and penetration of high - temperature and high - humidity air inside the chamber. The rounded - corner design of the inner chamber liner can better drain the condensate water on the side walls.
Refrigeration System Technology
1. 3D Refrigeration System Management Drawing.
2. Frequency Conversion Control Technology of the Refrigeration System: In the frequency conversion refrigeration system, even if the power supply frequency of 50Hz is fixed, the frequency can be changed through the frequency converter, thereby adjusting the rotational speed of the compressor, and making the cooling capacity change continuously. This ensures that the operating load of the compressor matches the actual load inside the test chamber (that is, when the temperature inside the test body rises, the frequency of the compressor increases to enhance the cooling capacity; conversely, when the temperature drops, the frequency of the compressor decreases to reduce the cooling capacity). This greatly saves unnecessary losses during operation and achieves the goal of energy conservation. At the beginning of the operation of the test chamber, the frequency of the compressor can also be increased to enhance the capacity of the refrigeration system and achieve the purpose of rapid cooling. The test chamber adopts a frequency conversion refrigeration system, which can accurately control the temperature inside the chamber, keep the temperature inside the chamber constant with small temperature fluctuations. At the same time, it can also ensure the stable suction and discharge pressures of the refrigeration system, making the operation of the compressor more stable and reliable. Electronic Expansion Flow Servo.
Refrigeration system technology and other energy-saving technologies
1. VRF technology based on the principle of PID + PWM (the electronic expansion valve controls the refrigerant flow according to the thermal energy working conditions) is adopted. The VRF technology based on the principle of PID + PWM (refrigerant flow control) enables energy-saving operation at low temperatures (the electronic expansion valve controls the refrigerant flow servo according to the thermal energy working conditions). In the low-temperature working state, the heater does not participate in the operation. By adjusting the refrigerant flow and direction through PID + PWM, and regulating the three-way flow of the refrigeration pipeline, the cold bypass pipeline, and the hot bypass pipeline, the temperature of the working chamber can be automatically kept constant. In this way, under low-temperature working conditions, the temperature of the working chamber can be automatically stabilized, and the energy consumption can be reduced by 30%. This technology is based on the ETS system electronic expansion valve of the Danish company Dan-foss and can be applied to adjust the refrigeration capacity according to different requirements for refrigeration capacity. That is, it can realize the adjustment of the refrigeration capacity of the compressor when different cooling rate requirements are met.
2. The technology of grouped design of two sets of compressors (large and small) can automatically start and stop according to the load working conditions (large series design). The refrigeration unit is configured with a binary cascade refrigeration system composed of a set of semi-hermetic compressors and a set of fully hermetic single-stage refrigeration systems. The purpose of the configuration is to intelligently start different compressor units according to the load working conditions inside the chamber and the requirements for the cooling rate, so as to achieve the best matching between the refrigeration capacity working conditions inside the chamber and the output power of the compressor. In this way, the compressor can operate in the best working condition range, which can extend the service life of the compressor. More importantly, compared with the traditional design of a single large set, the energy-saving effect is very obvious, and it can reach more than 30% (cooperating with the VRF technology during short-time constant temperature control).
Refrigeration circuit technology
The electrical components shall be installed according to the power distribution assembly drawings issued by the Technology Department during the power distribution layout operation.
Internationally renowned brands shall be selected: Omron, Sch-neider, and German Phoenix terminal blocks.
The wire codes shall be clearly marked. A time-honored domestic brand (Pearl River Cable) shall be selected to ensure the quality of the wires. For the control circuit, the minimum size of the selected wire is 0.75 square millimeter RV soft copper wire. For all main loads such as the motor compressor, the wire diameter shall be selected in accordance with the safety current standard for wiring in the EC wire trough.
The cable openings of the compressor terminal box shall be treated with sealant to prevent the terminals in the terminal box from short-circuiting due to frosting.
All the fixing screws of the terminals shall be tightened with the standard fixing torque to ensure reliable fastening and prevent potential hazards such as loosening and arcing.
Refrigeration series process
1. Standardization
1.1 Standardization of the piping process and welding of high-quality steel pipes; The piping layout shall be carried out in accordance with the standards to ensure the stable and reliable operation of the machine model system.
1.2 The steel pipes are bent in one piece by an imported Italian pipe bender, which greatly reduces the number of welding points and the internal pipe oxides generated during welding, and improves the reliability of the system!
2. Pipe Shock Absorption and Support
2.1 MENTEK has strict requirements for the shock absorption and support of the refrigeration copper pipes. Taking full account of the shock absorption situation of the pipes, circular arc bends are added to the refrigeration pipes, and special nylon fixing clamps are used for installation. This avoids the pipe deformation and leakage caused by circular vibration and temperature changes, and improves the reliability of the entire refrigeration system.
2.2 Oxidation-free Welding Process As is well known, the cleanliness inside the pipes of the refrigeration system is directly related to the efficiency and service life of the refrigeration system. MENTEK adopts standardized gas-filled welding operation to avoid a large amount of oxide contamination generated inside the pipes during welding.
Company Profile



Certifications
Ship to Client's Factory
Our Partners

Packaging & Shipping