Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester

Product Details
Customization: Available
After-sales Service: Support Operation Guidance
Power Supply: 380V
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (29)
  • Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
  • Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
  • Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
  • Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Certifications
  • Ship to Client′s Factory
  • Our Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
MESS
Certification
CE
Warranty
1 Year
City
Dongguan, Guangdong
Uses
Rapid Temperature Testing Machine
Purpose
Humid Temperature Testing Chamber
Observation Window
30*40/40*60cm
Transport Package
Wooden Box
Specification
MESS-280-1500
Trademark
MENTEK
Origin
China
HS Code
8479899990
Production Capacity
1000PCS/1year

Product Description

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Product Description

Product Features
1. The humidity control function is optional. The heating and cooling rate is adjustable, with the maximum rate reaching 20°C/min, and the auxiliary liquid nitrogen refrigeration can reach 30°C/min.

2. Equipped with a frequency converter, the wind speed can be adjusted, and it can be set to reduce the wind speed under a constant state. A dry air purging system is optional to prevent condensation and frosting inside the chamber and on the samples.

3. The design of cold output energy conservation has been recognized by a third-party testing institution. The energy-saving effect is very significant in a large refrigeration system.

 


Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental TesterRapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental TesterRapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Main Parameters

Model   MESS-280 MESS-500 MESS-1000 MESS-1500
Parameter Temperature range -40~+150ºC(-20+80ºC) - 70+150ºC(-55+80ºC)
Temperature fluctuation ±0.3ºC±0.5ºC
Temperature deviation ±
Humidity deviation ±3%RH(<75%RH)±5%RH  (≤75%RH)
Heating and cooling rate 5/10/15/20ºC/min
Standard load (aluminum ingot) 5kg 12kg 25kg 30kg
Structure Casing High strength cold-rolled steel plate double-sided fine powder baking paint
Inner wall SUS # 304 Stainless Steel 2B Panel
Thermal insulation material Glass fiber+polyurethane foam
Cooling system Cooling method Single stage mechanical refrigeration/cascade two-stage compressor refrigeration method
  refrigeration machine Imported compressor
Heater Strip heater
Observation window (mm) 300*400/400*600
Test hole (mm) 50 at left side 100 at right side
Temperature sensor Platinum resistance pt100
Controller Original Japanese imported 7-inch TFT touch screen
Recording device Built in paperless recorder function (can be externally printed)
Interface UCB interface connection operation
Inner size (cm) Width 70 80 100 130
Height 80 90 100 115
Depth 50 70 100 100
Height of motor cover 19 21 22 21
Power AC380V 50Hz Three-phase four-wire
Standard configuration 1 product user manual. 1 experimental report, 1 certificate of conformity and quality assurance certificate, 2 partitions, and 1 set of silicone rubber soft plugs
Meet the configuration requirements GB11158\GBT2423\GB/T2423.1/T2423.2/GBT24423.2GJB1500.3\GJB15.0
Notes
1. The external dimensions are determined according to the heating and cooling rate.
2. Water-cooled type (water temperature: 10~28°C, water pressure: 0.1~0.3 MPa to ensure the cooling performance).
3. The function of damp heat can be added.
4. A dry air purging system is optional.
5. The liquid nitrogen function (30°C/minute) is optional.
6. The above loads are standard loads, and the design can be adjusted according to customers' requirements.

 Structural technology
Structural Process
1. Company's Hardware Equipment:
1 imported German laser machine; 1 Amada AIRS - 255NT punching machine from Japan; more than 10 German carbon dioxide welding machines and argon arc welding machines. We use Autodesk Inventor 3D drawing software for 3D sheet metal disassembly drawing and virtual assembly design.

2. The outer shell is made of high - quality galvanized steel plates and finished with electrostatic powder spraying and baking paint.

3. The inner chamber is made of imported SUS#304 stainless steel and adopts the argon arc full - penetration welding process to prevent the leakage and penetration of high - temperature and high - humidity air inside the chamber. The rounded - corner design of the inner chamber liner can better drain the condensate water on the side walls.
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Refrigeration System Technology
1. 3D Refrigeration System Management Drawing.

2. Frequency Conversion Control Technology of the Refrigeration System: In the frequency conversion refrigeration system, even if the power supply frequency of 50Hz is fixed, the frequency can be changed through the frequency converter, thereby adjusting the rotational speed of the compressor, and making the cooling capacity change continuously. This ensures that the operating load of the compressor matches the actual load inside the test chamber (that is, when the temperature inside the test body rises, the frequency of the compressor increases to enhance the cooling capacity; conversely, when the temperature drops, the frequency of the compressor decreases to reduce the cooling capacity). This greatly saves unnecessary losses during operation and achieves the goal of energy conservation. At the beginning of the operation of the test chamber, the frequency of the compressor can also be increased to enhance the capacity of the refrigeration system and achieve the purpose of rapid cooling. The test chamber adopts a frequency conversion refrigeration system, which can accurately control the temperature inside the chamber, keep the temperature inside the chamber constant with small temperature fluctuations. At the same time, it can also ensure the stable suction and discharge pressures of the refrigeration system, making the operation of the compressor more stable and reliable. Electronic Expansion Flow Servo. 
Refrigeration system technology and other energy-saving technologies
1. VRF technology based on the principle of PID + PWM (the electronic expansion valve controls the refrigerant flow according to the thermal energy working conditions) is adopted. The VRF technology based on the principle of PID + PWM (refrigerant flow control) enables energy-saving operation at low temperatures (the electronic expansion valve controls the refrigerant flow servo according to the thermal energy working conditions). In the low-temperature working state, the heater does not participate in the operation. By adjusting the refrigerant flow and direction through PID + PWM, and regulating the three-way flow of the refrigeration pipeline, the cold bypass pipeline, and the hot bypass pipeline, the temperature of the working chamber can be automatically kept constant. In this way, under low-temperature working conditions, the temperature of the working chamber can be automatically stabilized, and the energy consumption can be reduced by 30%. This technology is based on the ETS system electronic expansion valve of the Danish company Dan-foss and can be applied to adjust the refrigeration capacity according to different requirements for refrigeration capacity. That is, it can realize the adjustment of the refrigeration capacity of the compressor when different cooling rate requirements are met.

2. The technology of grouped design of two sets of compressors (large and small) can automatically start and stop according to the load working conditions (large series design). The refrigeration unit is configured with a binary cascade refrigeration system composed of a set of semi-hermetic compressors and a set of fully hermetic single-stage refrigeration systems. The purpose of the configuration is to intelligently start different compressor units according to the load working conditions inside the chamber and the requirements for the cooling rate, so as to achieve the best matching between the refrigeration capacity working conditions inside the chamber and the output power of the compressor. In this way, the compressor can operate in the best working condition range, which can extend the service life of the compressor. More importantly, compared with the traditional design of a single large set, the energy-saving effect is very obvious, and it can reach more than 30% (cooperating with the VRF technology during short-time constant temperature control).
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Refrigeration circuit technology

The electrical components shall be installed according to the power distribution assembly drawings issued by the Technology Department during the power distribution layout operation.

Internationally renowned brands shall be selected: Omron, Sch-neider, and German Phoenix terminal blocks.

The wire codes shall be clearly marked. A time-honored domestic brand (Pearl River Cable) shall be selected to ensure the quality of the wires. For the control circuit, the minimum size of the selected wire is 0.75 square millimeter RV soft copper wire. For all main loads such as the motor compressor, the wire diameter shall be selected in accordance with the safety current standard for wiring in the EC wire trough.
The cable openings of the compressor terminal box shall be treated with sealant to prevent the terminals in the terminal box from short-circuiting due to frosting.

All the fixing screws of the terminals shall be tightened with the standard fixing torque to ensure reliable fastening and prevent potential hazards such as loosening and arcing. 
Refrigeration series process
1. Standardization

1.1 Standardization of the piping process and welding of high-quality steel pipes; The piping layout shall be carried out in accordance with the standards to ensure the stable and reliable operation of the machine model system.

1.2 The steel pipes are bent in one piece by an imported Italian pipe bender, which greatly reduces the number of welding points and the internal pipe oxides generated during welding, and improves the reliability of the system!
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
2. Pipe Shock Absorption and Support

2.1 MENTEK has strict requirements for the shock absorption and support of the refrigeration copper pipes. Taking full account of the shock absorption situation of the pipes, circular arc bends are added to the refrigeration pipes, and special nylon fixing clamps are used for installation. This avoids the pipe deformation and leakage caused by circular vibration and temperature changes, and improves the reliability of the entire refrigeration system.

2.2 Oxidation-free Welding Process As is well known, the cleanliness inside the pipes of the refrigeration system is directly related to the efficiency and service life of the refrigeration system. MENTEK adopts standardized gas-filled welding operation to avoid a large amount of oxide contamination generated inside the pipes during welding.
 
Company Profile

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental TesterRapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester

Certifications

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Ship to Client's Factory

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
 
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester
 
Our Partners

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester

Packaging & Shipping

Rapid Temperature Change Humidity Testing Chamber Quick Thermal Variation Environmental Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier