Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing

Product Details
Customization: Available
After-sales Service: Support Operation Guidance
Power Supply: 380V
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (29)
  • Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Certifications
  • Ship to Client′s Factory
  • Our Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
MESS
Certification
CE
Warranty
1 Year
City
Dongguan, Guangdong
Uses
Rapid Temperature Change Chamber
Purpose
Rapid Temperature Change Testing
Observation Window
300*400mm/400*600mm
Transport Package
Wooden Box
Specification
60*50*75cm
Trademark
MENTEK
Origin
China
HS Code
8514199000
Production Capacity
1000PCS/1year

Product Description

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Product Description

1. Temperature shock
1.1 The test objects are battery packs and systems.
1.2 The test object is placed in the alternating of (-40±2)ºC~(85±2)ºC. In the temperature environment,
The conversion time of the two extreme temperatures is within 30 minutes. The test subject is maintained for 8 hours in each extreme temperature environment and cycled 5 times. Observe at room temperature for 2 hours. 
1.3 Requirements: It is required that the battery pack or system has no leakage, shell rupture, fire or explosion and other phenomena. The insulation resistance value after the test is not less than 100Ω/V.    
2. Wet and hot cycle

2.1 The test objects are battery packs and systems.
2.2 Refer to GB/T2423 to perform test Dd, of which the highest temperature is +80ºC, and the number of cycles is 5 times.  At room temperature observe for 2h.

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Main parameters

Model   MESS-225 MESS-408 MESS-1000
Performance parameters Temperature range -40-+150ºC (temperature change range: -20+80ºC): -70+150ºC (temperature change range: -55+80ºC
Temperature fluctuation ±0.5ºC
Temperature deviation ≤±2ºC
Humidity deviation ±3%RH (<75%RH) ±5%RH (≤75%RH)
The rate of temperature rise and fall 5ºC min
Standard load 5kg aluminum ingot 12kg aluminum ingots 25kg aluminum ingots
Organization Outer casing High-strength cold-rolled steel plate double-sided fine powder baking paint
Inner wall SUS.#304 stainless steel 2B panel
Insulation material Glass fiber + polyurethane foam
Refrigeration system Refrigeration method Single-stage mechanical refrigeration/superimposed two-stage compressor refrigeration method
Chiller Imported compressors
Heater Electric heating wire heater
Observation window (mm) 300*400/400*600
Test hole (mm) One 50 on the left One 100 on the right
Temperature sensor Platinum resistance pt100
Controller Original Japanese imported 7 Cun TFT. Touch screen
Recording device Built-in paperless recorder function (external printing available)
Computer interface UCInterface connection operation
Internal size (cm) Wide 60 80 100
Tall 50 85 100
Deep 75 60 100
Motor cover height 190 210 220
Power supply Audio-visual380V 50HzSanxiang Wire Control + Grounding Wire
Standard configuration 1 copy of the product instruction manual. 1 copy of the experimental report, 1 copy of the qualification certificate and 1 copy of the quality assurance certificate, 2 partitions, a set of silicone rubber soft plugs
Meet the configuration China National Standard 11158\GBT.2423\GC./T2423.1/T2423.2/GBT.24423.2GJB.1500.3\GJB.15.0
Note:
1. The external size is determined by the rising and lowering temperature rate
2. Water-cooled type (water temperature 10-28ºC, water pressure 0.1-0.3Mpa, in order to ensure cooling performance)

3. It can increase the wet and hot function
4. Optional dry air blowing system
5. Optional liquid nitrogen function (30ºC/minute)
6. The above load is a standard load and can be designed according to customer requirements.

 
Company Profile

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power TestingBattery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing

Certifications

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Ship to Client's Factory

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
 
Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing
Our Partners

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing

Packaging & Shipping

Battery Rapid Temperature Change Chamber for Reliable Results Mess Series Power Testing




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier