Customization: | Available |
---|---|
After-sales Service: | Support Operation Guidance |
Power Supply: | 380V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Relevant Standard Testing Requirements
Meet the standards: IEC62133-2012, UL1642, UN38.3 and 31241-2014 standards.
Temperature Cycling Test Chamber: After fully charging the battery according to the test method specified in 4.5.1, place the battery in the test chamber and conduct the test according to the following steps (see Figure 1):
a) Maintain the temperature at 75°C ± 2°C for 6 hours;
b) Maintain the temperature at -40°C ± 2°C for 6 hours;
c) Repeat steps a) to b), with a total of 10 cycles;
d) Restore the ambient temperature to 20°C ± 5°C.
The conversion time between every two temperatures during the test process shall not be longer than 30 minutes.
Main Parameters
Model | MHP-150 | MHP-225 | MHP-408 | MHP-800 | MHP-1000 | |||||||||||||||||||||||||||||||||||||
Inner box size W*H*D(cm) | 50*60*50 | 60*75*50 | 80*85*60 | 100*100*80 | 100*100*100 | |||||||||||||||||||||||||||||||||||||
Outer box size W*H*D(cm) | 70*150*165 | 80*165*170 | 100*175*180 | 120*190*185 | 120*190*190 | |||||||||||||||||||||||||||||||||||||
The volume of the inner box | 150L | 225L | 408L | 800L | 1000L | |||||||||||||||||||||||||||||||||||||
Performance | Temperature and humidity range | 0ºC/20°ºC/-40°C/-60C/-70ºC/+100ºC(+150ºC): 10%RH-98% | ||||||||||||||||||||||||||||||||||||||||
Volatility of temperature and humidity | ±0.3ºC-±0.5ºC; ±2.5%RH | |||||||||||||||||||||||||||||||||||||||||
Temperature and humidity deviation | ±2ºC; Soil 3RH(>75%RH); Soil 5%RH ≤75 % RH) | |||||||||||||||||||||||||||||||||||||||||
Controller analysis accuracy | ±0.01ºC; ±0.1%RH | |||||||||||||||||||||||||||||||||||||||||
Warm-up time | 100 | 150 | 100 | 150 | 100 | 150 | 100 | 150 | 100 | 150 | ||||||||||||||||||||||||||||||||
(RT-HT) | 30 | 40 | 40 | 50 | 45 | 55 | 55 | 60 | 50 | 60 | ||||||||||||||||||||||||||||||||
Cooling time | 0 | -20 | -40 | -60 | -70 | 0 | -20 | -40 | -60 | -10 | 0 | -20 | -40 | -60 | -70 | 0 | -20 | 40 | -60 | -70 | 0 | -20 | -40 | -60 | -70 | |||||||||||||||||
RT-HT | 40 | 50 | 55 | 90 | 100 | 40 | 50 | 55 | 90 | 100 | 40 | 50 | 55 | 90 | 100 | 40 | 50 | 55 | 90 | 100 | 40 | 50 | 55 | 90 | 100 | |||||||||||||||||
Power supply (kW) | 3.0 | 4.0 | 6.0 | 6.0 | 6.0 | 3.5 | 5.5 | 6.5 | 8.0 | 8.5 | 4.5 | 6.0 | 7.5 | 9.5 | 9.5 | 5.5 | 9.0 | Ten | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | |||||||||||||||||
Weight (kg) | 250 | 300 | 400 | 600 | 700 | |||||||||||||||||||||||||||||||||||||
Material | Inner wall | SUS#304 stainless steel 2B panel | ||||||||||||||||||||||||||||||||||||||||
Outer casing | High-strength cold-rolled steel plate double-sided fine powder baking paint | |||||||||||||||||||||||||||||||||||||||||
System wind circuit | Glass fiber + polyurethane foam | |||||||||||||||||||||||||||||||||||||||||
System | Way | Centrifugal fan one broadband forced airflow circulation (top out and down) | ||||||||||||||||||||||||||||||||||||||||
Refrigeration method | Single-stage mechanical compression refrigeration (or binary stacked refrigeration) | |||||||||||||||||||||||||||||||||||||||||
Chiller | Single fully enclosed piston type French Taikang compressor | |||||||||||||||||||||||||||||||||||||||||
Refrigerant | R404A American Shebang Environmental Protection Cold Coal (R23+404A) | |||||||||||||||||||||||||||||||||||||||||
Condensation method | Air-cooled or water-cooled | |||||||||||||||||||||||||||||||||||||||||
Heater | Alloy electric heating wire heater | |||||||||||||||||||||||||||||||||||||||||
Humidifier | Semi-closed steam humidification (boiler type) | |||||||||||||||||||||||||||||||||||||||||
Water supply method | For fully automatic circulating water supply (water quality requires resistivity>500 M) | |||||||||||||||||||||||||||||||||||||||||
Standard configuration | 1 observation window (double-layer insulated tempered glass); 1 test hole 50mm (located on the left); 2-layer sample rack; 1 box lighting fixture (fluorescent lamp); 1 pack of gauze; 8 hooks; 2 fuses; 4 small wheels; 1 power cord | |||||||||||||||||||||||||||||||||||||||||
Safe protect | Equipped with an explosion-proof pressure relief port, the box door is equipped with an explosion-proof chain, and the observation window is equipped with an explosion-proof grid. Optional smoke alarm, smoke exhaust pipe, video surveillance and fire extinguishing system. |