Relevant standard test requirements
1.1 The test object is the battery system.
1.2 All control systems of the test object in the test should be in working condition.
1.3 Short-circuit the terminal of the test object 10min.
1.4 The short-circuit resistance shall not be greater than 20mΩ, which shall be mutually agreed upon by both parties.Observe 2h.
1.5 Requirements: The protective device works. The battery system has no leakage, shell rupture, fire or explosion and other phenomena. Insulation after the test The resistance value is not less than 100Ω/V.
Main parameters
Name of the equipment | High current short-circuit test device |
Model | MBS-DL15000A |
Maximum working current | 15000A |
Maximum instantaneous current | 16000A |
Internal resistance device | Normal temperature |
Control method | ≤5mΩ |
Dimensions of the host | PLC Touch screen+remote computer control+remote control |
The size of the inner box of the explosion-proof box | W1150*D1250*H1780mm |
Security apparatus | W1000*D1000*H1000mm |
Data acquisition module | Independent remote collection and isolation. Multiple voltage, temperature, current collection channel. Make sure that the collection is correct. Acquisition frequency 100Hz. |
Short circuit method | Pneumatic+vacuum arc extinguishing |
Safety alarm | Power leakage, overcurrent protection, abnormal sound and light alarm, smoke alarm, etc. |
Test fixture | Special customization. Follow up the actual use conditions of the test products. |
Power supply voltage | 220V 50Hz. |