HE Series Expansion Table Fixture Vibration Testing Equipment
Product Description
Product Usage
In actual vibration testing, the specimen or fixture is often larger than the moving coil table of the electric table. In this case, it is necessary to expand the original table, and a common method is to install an auxiliary expansion table. There are strict requirements for the expansion table in terms of operating frequency, table weight, table acceleration, amplitude uniformity, and lateral motion.
The HE series expansion table provides a larger installation table than the dynamic coil for vertical testing. The expansion table is made of lightweight magnesium or aluminum table metal materials, which have a high strength to weight ratio.
For small-sized fixtures, cheaper aluminum table metal materials can be chosen, which will result in a smaller increase in overall quality. The expansion table can test multiple projects simultaneously, reducing testing time.
The expansion table with load support guidance can reliably install and test large-sized specimens, reducing the risk of damaging the vibration table suspension system.
The guided expansion table can be used to simulate testing large and heavy equipment under harsh transportation conditions, and can also be used to test equipment with additional constraints and loads and more stringent testing conditions.
The fixtures can also be designed and manufactured according to the installation needs of the customer's test samples. Cube shaped and L-shaped T-shaped fixtures can be used for testing multiple small-sized parts. For triaxial testing, cubic, L-shaped, and T-shaped fixtures are preferred by customers and do not require the addition of a horizontal slide table.
The design of fixtures is carried out using software for monthly FEM calculation, which ensures the design of fixtures with superior dynamic performance.
Product Features
Precision machining table, with a uniform surface
There are requirements for the overall motion quality, and monthly magnesium table gold fixtures can be selected
FEM fixture design
Circular, square, and octagonal expansion countertops
Available frequency up to 2000Hz
Can be used in conjunction with insulation pads and temperature control boxes
Economically efficient expansion testing method
The first-order resonance frequency is high, determined by the size
The size of the screw hole for desktop installation is optional
Design and use in conjunction with the customer's existing vibration table system

HE series vertical expansion table top
1. The equivalent mass and efficiency range in the table represent aluminum vertical expansion tables.
The equivalent mass of magnesium expansion tables decreases to 65% of aluminum expansion tables of the same model, reducing the monthly frequency range to 90% of aluminum expansion tables of the same model.
2. Standard fabric holes:
HE 300SQ/A (HE 300 RD/A) to HE 500S0/A (HE 500 RD/A) use 80*80mm rectangular fabric holes.
HE 600SQ/A (HE 600 RD/A) to HEl200 SQ/A (HEl200 RD/A) use 100*100mm rectangular holes.
3. Standard format for ordering expansion stations.
Square Vertical Expansion Platform Parameters
Model
Table diameter |
L215M
L315M |
L620M |
M124M |
M232A
LS232A |
M437A
LS444A |
M544A |
M748A
H844A
H1248A |
H1859A |
HE300 SQ/A |
10
200 |
10
2000 |
|
|
|
|
|
|
HE400 SQ/A |
12
2000 |
14
2000 |
24
2000 |
|
|
|
|
|
HE500 SQ/A |
16
1700 |
25
1700 |
25
2000 |
37
1800 |
40
2000 |
|
|
|
HE600 SQ/A |
|
35
1500 |
42
1500 |
45
2000 |
50
2000 |
60
2000 |
|
|
HE700 SQ/A |
|
45
1000 |
50
1200 |
55
1500 |
60
1700 |
80
2000 |
|
|
HE800 SQ/A |
|
60
800 |
60
800 |
70
1200 |
80
1200 |
85
1000 |
100
1500 |
100
1500 |
HE900 SQ/A |
|
|
65
500 |
90
800 |
95
1000 |
100
1000 |
120
1000 |
120
1000 |
HE1000 SQ/A |
|
|
73
300 |
100
500 |
120
800 |
150
1000 |
150
1000 |
150
1000 |
HE1100 SQ/A |
|
|
|
|
|
180
500 |
180
700 |
180
700 |
HE1200 SQ/A |
Equal effect quality (kg)
Upper limit frequency (Hz) |
|
|
|
200
400 |
200
400 |
200
400 |
Circular Vertical Expansion Platform Parameters
Model
Table diameter |
L215M
L315M |
L620M |
M124M |
M232A
LS232A |
M437A
LS444A |
M544A |
M748A
H844A
H1248A |
H1859A |
HE300 SQ/A |
10
2000 |
7
2000 |
|
|
|
|
Equal effect quality (kg)
Upper limit frequency (Hz) |
HE400 SQ/A |
12
2000 |
12
2000 |
18
2000 |
|
|
|
|
|
HE500 SQ/A |
12
1600 |
12
2000 |
20
2000 |
25
1500 |
25
2000 |
|
|
|
HE600 SQ/A |
|
15
1800 |
22
1200 |
30
1000 |
33
2000 |
40
2000 |
|
|
HE700 SQ/A |
|
20
1000 |
30
800 |
40
700 |
45
1700 |
60
1700 |
|
|
HE800 SQ/A |
|
|
|
55
800 |
60
1200 |
70
1500 |
|
|
HE900 SQ/A |
|
|
|
|
65
1000 |
100
1200 |
|
|
HE1000 SQ/A |
|
|
|
|
|
130
1400 |
140
1400 |
150
1600 |
HE1100 SQ/A |
|
|
|
|
|
150
700 |
170
800 |
180
900 |
HE1200 SQ/A |
Equal effect quality (kg)
Upper limit frequency (Hz) |
|
|
|
200
500 |
200
500 |
200
500 |
HE1500 SQ/A |
|
|
|
|
|
300
250 |
350
350 |
400
300 |
Craftsmanship
Structural Process
1. Company's Hardware Equipment:
1 imported German laser machine; 1 Amada AIRS - 255NT punching machine from Japan; more than 10 German carbon dioxide welding machines and argon arc welding machines. We use Autodesk Inventor 3D drawing software for 3D sheet metal disassembly drawing and virtual assembly design.
2. The outer shell is made of high - quality galvanized steel plates and finished with electrostatic powder spraying and baking paint.
3. The inner chamber is made of imported SUS#304 stainless steel and adopts the argon arc full - penetration welding process to prevent the leakage and penetration of high - temperature and high - humidity air inside the chamber. The rounded - corner design of the inner chamber liner can better drain the condensate water on the side walls.
Refrigeration System Technology
1. 3D Refrigeration System Management Drawing.
2. Frequency Conversion Control Technology of the Refrigeration System: In the frequency conversion refrigeration system, even if the power supply frequency of 50Hz is fixed, the frequency can be changed through the frequency converter, thereby adjusting the rotational speed of the compressor, and making the cooling capacity change continuously. This ensures that the operating load of the compressor matches the actual load inside the test chamber (that is, when the temperature inside the test body rises, the frequency of the compressor increases to enhance the cooling capacity; conversely, when the temperature drops, the frequency of the compressor decreases to reduce the cooling capacity). This greatly saves unnecessary losses during operation and achieves the goal of energy conservation. At the beginning of the operation of the test chamber, the frequency of the compressor can also be increased to enhance the capacity of the refrigeration system and achieve the purpose of rapid cooling. The test chamber adopts a frequency conversion refrigeration system, which can accurately control the temperature inside the chamber, keep the temperature inside the chamber constant with small temperature fluctuations. At the same time, it can also ensure the stable suction and discharge pressures of the refrigeration system, making the operation of the compressor more stable and reliable. Electronic Expansion Flow Servo.
Refrigeration system technology and other energy-saving technologies
1. VRF technology based on the principle of PID + PWM (the electronic expansion valve controls the refrigerant flow according to the thermal energy working conditions) is adopted. The VRF technology based on the principle of PID + PWM (refrigerant flow control) enables energy-saving operation at low temperatures (the electronic expansion valve controls the refrigerant flow servo according to the thermal energy working conditions). In the low-temperature working state, the heater does not participate in the operation. By adjusting the refrigerant flow and direction through PID + PWM, and regulating the three-way flow of the refrigeration pipeline, the cold bypass pipeline, and the hot bypass pipeline, the temperature of the working chamber can be automatically kept constant. In this way, under low-temperature working conditions, the temperature of the working chamber can be automatically stabilized, and the energy consumption can be reduced by 30%. This technology is based on the ETS system electronic expansion valve of the Danish company Dan-foss and can be applied to adjust the refrigeration capacity according to different requirements for refrigeration capacity. That is, it can realize the adjustment of the refrigeration capacity of the compressor when different cooling rate requirements are met.
2. The technology of grouped design of two sets of compressors (large and small) can automatically start and stop according to the load working conditions (large series design). The refrigeration unit is configured with a binary cascade refrigeration system composed of a set of semi-hermetic compressors and a set of fully hermetic single-stage refrigeration systems. The purpose of the configuration is to intelligently start different compressor units according to the load working conditions inside the chamber and the requirements for the cooling rate, so as to achieve the best matching between the refrigeration capacity working conditions inside the chamber and the output power of the compressor. In this way, the compressor can operate in the best working condition range, which can extend the service life of the compressor. More importantly, compared with the traditional design of a single large set, the energy-saving effect is very obvious, and it can reach more than 30% (cooperating with the VRF technology during short-time constant temperature control).
Refrigeration circuit technology
The electrical components shall be installed according to the power distribution assembly drawings issued by the Technology Department during the power distribution layout operation.
Internationally renowned brands shall be selected: Omron, Sch-neider, and German Phoenix terminal blocks.
The wire codes shall be clearly marked. A time-honored domestic brand (Pearl River Cable) shall be selected to ensure the quality of the wires. For the control circuit, the minimum size of the selected wire is 0.75 square millimeter RV soft copper wire. For all main loads such as the motor compressor, the wire diameter shall be selected in accordance with the safety current standard for wiring in the EC wire trough.
The cable openings of the compressor terminal box shall be treated with sealant to prevent the terminals in the terminal box from short-circuiting due to frosting.
All the fixing screws of the terminals shall be tightened with the standard fixing torque to ensure reliable fastening and prevent potential hazards such as loosening and arcing.
Refrigeration series process
1. Standardization
1.1 Standardization of the piping process and welding of high-quality steel pipes; The piping layout shall be carried out in accordance with the standards to ensure the stable and reliable operation of the machine model system.
1.2 The steel pipes are bent in one piece by an imported Italian pipe bender, which greatly reduces the number of welding points and the internal pipe oxides generated during welding, and improves the reliability of the system!
2. Pipe Shock Absorption and Support
2.1 MENTEK has strict requirements for the shock absorption and support of the refrigeration copper pipes. Taking full account of the shock absorption situation of the pipes, circular arc bends are added to the refrigeration pipes, and special nylon fixing clamps are used for installation. This avoids the pipe deformation and leakage caused by circular vibration and temperature changes, and improves the reliability of the entire refrigeration system.
2.2 Oxidation-free Welding Process As is well known, the cleanliness inside the pipes of the refrigeration system is directly related to the efficiency and service life of the refrigeration system. MENTEK adopts standardized gas-filled welding operation to avoid a large amount of oxide contamination generated inside the pipes during welding.
Company Profile



Certifications
Ship to Client's Factory