Customization: | Available |
---|---|
After-sales Service: | Support Operation Guidance |
Power Supply: | 380V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Relevant standard test requirements
1.1 The test object is the battery pack or system
1.2 Pressurization according to the following conditions
1.2.1 Extruded plate form: plate garden cylinder with a radius of 75mm, the long line of semi-cylindrical body is larger than the test. The height of the object, but not more than 1mm.
1.2.2 Squeezing direction: X and Y direction (the driving direction of the car is the X axis, and the other horizontal direction perpendicular to the driving direction is the Y axis).
1.2.3 Squeezing degree: Stop squeezing when the squeezing force reaches 200KN or the extrusion deformation reaches 30% of the overall size of the squeezing direction.
1.2.4 Maintain for 10min and observe for 1h
1.3 Requirements: The battery pack or system does not catch fire or explode and so on.
Main Parameters
Name of the equipment | Squeezing needle and piercing all-in-one machine |
Model | MBS-JZ500 |
Pressure | 50 T |
Squeezing method | Crosswise |
Box structure | Horizontal box structure |
Test space (W*H*D) mm | 2500*2000*2000 |
Power supply voltage | Ac380V 50Hz |
Squeezing speed | 1-10mm/s (Adjustable) |
Needle puncture speed | 1-100mm/Small size (Adjustable) |
Test conditions | Force, displacement (deformation) , voltage, one of the three or a combination of three |
Driving mode | Oil-pressure servo drive |
Squeezing accuracy | ≤±1% (FSR.) |
Acupuncture accuracy | ≤±1% (FSR.) |
The amount of extrusion deformation | 0~ 100% multi-gear work cloth setting, can be realized continuously multi-layer extrusion deformation loading |
Squeezing fixture | Shaped squeezing head (400*150mm) flat squeeze plate, arc squeeze plate (radius75mm). It can be according to different standard optional different fixtures |
Data acquisition module | Multiple data acquisition module, temperature, voltage and current are collected. The road adopts N×4 mode. It is convenient to expand when necessary in the future, make sure that the data is correct |
Safety alarm | Leakage, overheating, overvoltage, overload, overcurrent protection, abnormality sound and light alarm, smoke alarm, etc. |
Control method | Device host and remote PC control, device body and console. Separate, can be controlled remotely, and the operator should stay away from the test area. The longest long-distance distance can reach 50 meters, and the standard line length is 10m. It can effectively protect the safety of testers. |